abbr. SJ GMU
ISSN 2657-5841 (printed)
ISSN 2657-6988 (online)
DOI: 10.26408
Oxygen Transfer Measurements at Surface Aerators in Waste Water as Basis for Energy Saving in Aeration
Oxygen transfer measurements were carried out in order to compare surface aerators under operating conditions in waste water. A simple method was used without using chemicals like cobalt or sulfite. Results show incomplete mixing of basins at high biological activity that lead to mass transfer data not comparable with data of standardized fresh water tests, but different types of aerators could be compared under local operating conditions as basis for investment decisions.
DWA 2007: Deutsche Vereinigung für Wasserwirtschaft, Abwasser und Abfall e.: DWA-Method M209 „Messung der Sauerstoffzufuhr von Belüftungseinrichtungen in Belebungsanlagen in Reinwasser und in belebtem Schlamm“, GFA, Hennef 2007.